联系我们   Contact
你的位置:首页 > PRODUCTS > Air Cooler

New-model of High-performance Air Cooler

产品介绍
Description:
Model AX-D series Ceiling-type Air Cooler is categorized according to the temperature of the refrigerator. Model DL is for temperature at±0℃, Model DD for temperature at -18℃, and Model DJ for temperature at -25℃. The refrigerating capacity of refrigerant R22 ranges from 1.1 to 81Kw.
Description:
Model AX-D series Ceiling-type Air Cooler is categorized according to the temperature of the refrigerator. Model DL is for temperature at±0℃, Model DD for temperature at -18℃, and Model DJ for temperature at -25℃. The refrigerating capacity of refrigerant R22 ranges from 1.1 to 81Kw.

Features
1、Aluminum-rolled housing, plastic-sprayed coat, corrosive-proof, anti-rust, scratchproof, elegant in style.
2、Double-layer water receiver, side board movable to take apart easily, convenient for maintenance.
3、Coil is in form of female-threaded brass tube that’s expanded by hydraulic way and cleaned with trichloroethylene, free of any impurity. The fin is in form of dual-hem aluminum panel that makes frosting evenly, high in efficiency of heat conduction, quick to lower temperature.
4、Adoption of WYS series outer-rotor axial fan, small in start current, large in air volume, low in noise, and stable in operation.
5、U-shaped electro-thermal tube that’s desirable in insulation. The internal gap is evenly arranged, rational in power capacity, good in defrosting effect.
6、Silver welding for bend joint, pressure test up to 2.6 Mpa. Nitrogen filled to keep pressure before it’s out of factory. Stable in quality.
7、For the air cooler that’s same in fin area, the one with female-threaded brass tube is 1.4-1.5 times higher in refrigerating capacity than that with only simply tube.

Model Designation

New and High-performance Series Air Cooler
Main Technical Parameter of DD Series Air-Cooler
型号Model 名义制冷量
W(Kcal/h)
冷却面积 片距 风扇电机Fan Motor 电热管heating tube 备注
数量 直径Φ 风量 射程 电机功率 电压 盘管 水盘 电压
m2 mm mm m3/h m W V KW KW V 可用于
R134a
R404A
R407C

R502
AX-DD9-S301 2700(2300) 9.4 6 1 300 1800 9 80 220/380 1.2 0.6 220
AX-DD12-S351 3600(3100) 12.2 6 1 360 2500 12 160 220/380 1.8 0.9 220
AX-DD15-S302 4500(3870) 15 6 2 300 2×1800 9 80 220/380 1.8 0.9 220
AX-DD22-S302 6600(5680) 22.4 6 2 300 2×1800 9 80 220/380 2.4

1.2

220
AX-DD30-S303 9000(7740) 31 6 3

300

3×1800 9 80 220/380 2.7 1.2 220
AX-DD40-S304 12000(10300) 405 6 4 300 4×1800 9 80 220/380 3.0 1.5 220
AX-DD45-S304 13500(11600) 44.5 6 4 300 4×1800 9 80 220/380 3.6 1.5 220
AX-DD60-S404 18000(15500) 61 6 4 400 4×3600 14 180 220/380 6.5 1.5 220
AX-DD75-S404 22500(19400) 75 6 4 400 4×3600 14 180 220/380 6.5 1.5 220
AX-DD90-S404 27000(23200) 89 6 4 400 4×3600 14 180 220/380 9.0 1.8 220
AX-DD105-S454 31500(27100) 106 6 4 450 4×5200 18 250 220/380 9.0 1.8 220
AX-DD120-S454 36000(31000) 121 6 4 450 4×5200 18 250 220/380 9.0 1.8 220
AX-DD135-S455 39000(33500) 134.5 6 5 450 5×5200 18 250 220/380 10.0 1.8 220
AX-DD145-S455 42000(36100) 143.5 6 5 450 5×5200 18 250 220/380 12.5 2.5 220
AX-DD160-S455 44800(38500) 158 6 5 450 5×5200 18 250 220/380 12.5 2.5 220
AX-DD185-S505 51800(44500) 187 6 5 500 5×6500 20 400 220/380 15.0 2.5 220
AX-DD200-S505 56000(48200) 203 6 5 500 5×6500 20 400 220/380 20.0 2.5 220
As for the refrigerating capacity of R22 under condition of tk=-18℃ and △t=7℃, the refrigerating capacity of R134a should be multiplied the correction factor Qor 134a=Qor 22×f

Correction factor Table f
R134a
蒸发温度to >-12℃ >-17℃ >-22℃ >-27℃
Qo 1.00 0.96 0.93 0.90

New and High-performance Series Air Cooler
Main Technical Parameter of DJ Series Air-Cooler
型号Model 名义制冷量
W(Kcal/h)
冷却面积 片距 风扇电机Fan Motor 电热管heating tube 备注
数量 直径Φ 风量 射程 电机功率 电压 盘管 水盘 电压
m2 mm mm m3/h m W V KW KW V 可用于
R134a
R404A
R407C

R502
AX-DJ7-S301 1960(1680) 6.3 9 1 300 1800 9 80 220/380 1.2 0.6 220
AX-DJ9-S351 2520(2170) 8.2 9 1 360 2500 12 160 220/380 1.8 0.9 220
AX-DJ10-S302 2800(2400) 10 9 2 300 2×1800 9 80 220/380 1.8 0.9 220
AX-DJ15-S302 4200(3600) 15 9 2 300 2×1800 9 80 220/380 2.4 1.2 220
AX-DJ22-S303 6160(5300) 21 9 3 300 3×1800 9 80 220/380 3.0 1.2 220
AX-DJ27-S304 7560(6500) 27 9 4 300 4×1800 9 80 220/380 3.0 1.2 220
AX-DJ30-S304 8400(7220) 30 9 4 300 4×1800 9 80 220/380 3.6 1.5 220
AX-DJ40-S404 11200(9630) 40.5 9 4 400 4×3600 14 180 220/380 4.5 1.5 220
AX-DJ50-S404 14000(12000) 50 9 4 400 4×3600 14 180 220/380 6.5 1.8 220
AX-DJ60-S404 16800(14400) 60 9 4 400 4×3600 14 180 220/380 7.5 1.8 220
AX-DJ70-S454 18900(16200) 71 9 4 450 4×5200 18 250 220/380 9.0 1.8 220
AX-DJ80-S454 21600(18600) 81 9 4 450 4×5200 18 250 220/380 9.0 1.8 220
AX-DJ90-S455 24300(21000) 89 9 5 450 5×5200 18 250 220/380 12.5 2.5 220
AX-DJ95-S455 24900(21400) 95 9 5 450 5×5200 18 250 220/380 12.5 2.5 220
AX-DJ105-S455 27300(23500) 104 9 5 450 5×5200 18 250 220/380 15.0 2.5 220
AX-DJ125-S505 32500(27900) 125 9 5 500 5×6500 20 400 220/380 20.0 2.5 220
AX-DJ135-S505 35100(30200) 135 9 5 500 5×6500 20 400 220/380 22.5 2.5 220
As for the refrigerating capacity of R22 under condition of tk=-25℃ and △t=7℃, the refrigerating capacity of R134a should be multiplied the correction factor Qor 134a=Qor 22×f

Correction factor Table f
R134a
蒸发温度to >-12℃ >-17℃ >-22℃ >-27℃
Qo 1.00 0.96 0.93 0.90

New and High-performance Series Air Cooler
Main Technical Parameter of DL Series Air-Cooler
型号Model 名义制冷量
W(Kcal/h)
冷却面积 片距 风扇电机Fan Motor 电热管heating tube 备注
数量 直径Φ 风量 射程 电机功率 电压 盘管 水盘 电压
m2 mm mm m3/h m W V KW KW V 可用于
R134a
R404A
R407C

R502
AX-DL12-S301 3840(3300) 12 4.5 1 300 1800 9 80 220/380 0.6 0.6 220
AX-DL16-S351 5120(4400) 16 4.5 1 350 2500 12 150 220/380 0.9 0.6 220
AX-DL20-S302 6400(5500) 20 4.5 2 300 2×1800 9 80 220/380 0.9 0.6 220
AX-DL30-S302 9600(8250) 30 4.5 2 300 2×1800 9 80 220/380 1.2 0.6 220
AX-DL45-S303 14400(12400) 42 4.5 3 300 3×1800 9 80 220/380 1.8 0.9 220
AX-DL55-S304 17600(15100) 54 4.5 4 300 4×1800 9 80 220/380 1.8 0.9 220
AX-DL60-S304 19200(16500) 60 4.5 4 300 4×1800 9 80 220/380 2.4 1.2 220
AX-DL80-S404 25600(22000) 81 4.5 4 400 4×3600 14 180 220/380 2.4 1.2 220
AX-DL100-S404 32000(27500) 100 4.5 4 400 4×3600 14 180 220/380 3.6 1.5 220
AX-DL120-S404 36000(31000) 118 4.5 4 400 4×3600 14 180 220/380 5.0 1.8 220
AX-DL140-S454 42000(36100) 142 4.5 4 450 4×5200 18 250 220/380 5.0 1.8 220
AX-DL160-S454 48000(41300) 162 4.5 4 450 4×5200 18 250 220/380 6.5 1.8 220
AX-DL180-S455 54000(46400) 178 4.5 5 450 5×5200 18 250 220/380 6.5 1.8 220
AX-DL190-S455 57000(49000) 191 4.5 5 450 5×5200 18 250 220/380 7.5 2.5 220
AX-DL210-S455 63000(54200) 208 4.5 5 450 5×5200 18 250 220/380 7.5 2.5 220
AX-DL250-S505 75000(64500) 249 4.5 5 500 5×6500 20 400 220/380 9.0 2.5 220
AX-DL270-S505 81000(69700) 270 4.5 5 500 5×6500 20 400 220/380 10.0 2.5 220
As for the refrigerating capacity of R22 under condition of tk=0℃ and △t=7℃, the refrigerating capacity of R134a should be multiplied the correction factor Qor 134a=Qor 22×f

Correction factor Table f
R134a
蒸发温度to >-12℃ >-17℃ >-22℃ >-27℃
Qo 1.00 0.96 0.93 0.90

Installation Size of New and High-performance Series Air Cooler
Technical Parameters
型号Model A B C D E E1 E2 F 进液直径Φ(mm) 回气直径Φ(mm) 出水管直径Φ
AX-DL12-S301
AX-DD9-S301
AX-DJ7-S301
820 400 470 370 510 155 12 19 G1"
AX-DL16-S351
AX-DD12-S351
AX-DJ9-S351
880 400 540 370 570 155 12 22
AX-DL20-S302
AX-DD15-S302
AX-DJ10-S302
1000 400 540 370 690 155 12 22
AX-DL30-S302
AX-DD22-S302
AX-DJ15-S302
1320 400 540 370 1010 155 12 22

AX-DL45-S303
AX-DD30-S303
AX-DJ22-S303

1720 400 540 370 1410 155 16 28

AX-DL55-S304
AX-DD40-S304
AX-DJ27-S304

2100 400 540 370 1790 880 155 16 28
AX-DL60-S304
AX-DD45-S304
AX-DJ30-S304
2300 400 540 370 1990 980 155 16 28
AX-DL80-S404
AX-DD60-S404
AX-DJ40-S404
2420 410 680 370 2110 1040 155 16 32

AX-DL100-S404
AX-DD75-S404
AX-DJ50-S404

2900 410 680 370 2590 1280 155 22 32
AX-DL120-S404
AX-DD90-S404
AX-DJ60-S404
3040 410 750 370 2730 1350 155 22 32
AX-DL140-S454
AX-DD105-S454
AX-DJ70-S454
3040 420 890 370 2730 1350 155 22 32
AX-DL160-S454
AX-DD120-S454
AX-DJ80-S454
2820 480 890 430 2510 1240 155 22 32
AX-DL180-S455
AX-DD135-S455
AX-DJ90-S455
3040 480 890 430 2730 1080 540 155 25 42 G3/2"
AX-DL190-S455
AX-DD145-S455
AX-DJ95-S455
3240 480 890 430 2930 1160 580 155 25 42

AX-DL210-S455
AX-DD160-S455
AX-DJ105-S455

3490 480 890 430 3180 1260 630 155 25 42
AX-DL250-S505
AX-DD185-S505
AX-DJ125-S505
3490 550 890 480 3180 1260 630 155 25 50
AX-DL270-S505
AX-DD200-S505
AX-DJ135-S505
3490 550 960 480 3180 1260 630 155 25 50
Note: We reserve the right to make technical modification without prior notice.

Features
1、Aluminum-rolled housing, plastic-sprayed coat, corrosive-proof, anti-rust, scratchproof, elegant in style.
2、Double-layer water receiver, side board movable to take apart easily, convenient for maintenance.
3、Coil is in form of female-threaded brass tube that’s expanded by hydraulic way and cleaned with trichloroethylene, free of any impurity. The fin is in form of dual-hem aluminum panel that makes frosting evenly, high in efficiency of heat conduction, quick to lower temperature.
4、Adoption of WYS series outer-rotor axial fan, small in start current, large in air volume, low in noise, and stable in operation.
5、U-shaped electro-thermal tube that’s desirable in insulation. The internal gap is evenly arranged, rational in power capacity, good in defrosting effect.
6、Silver welding for bend joint, pressure test up to 2.6 Mpa. Nitrogen filled to keep pressure before it’s out of factory. Stable in quality.
7、For the air cooler that’s same in fin area, the one with female-threaded brass tube is 1.4-1.5 times higher in refrigerating capacity than that with only simply tube.

Model Designation

New and High-performance Series Air Cooler
Main Technical Parameter of DD Series Air-Cooler
型号Model 名义制冷量
W(Kcal/h)
冷却面积 片距 风扇电机Fan Motor 电热管heating tube 备注
数量 直径Φ 风量 射程 电机功率 电压 盘管 水盘 电压
m2 mm mm m3/h m W V KW KW V 可用于
R134a
R404A
R407C

R502
AX-DD9-S301 2700(2300) 9.4 6 1 300 1800 9 80 220/380 1.2 0.6 220
AX-DD12-S351 3600(3100) 12.2 6 1 360 2500 12 160 220/380 1.8 0.9 220
AX-DD15-S302 4500(3870) 15 6 2 300 2×1800 9 80 220/380 1.8 0.9 220
AX-DD22-S302 6600(5680) 22.4 6 2 300 2×1800 9 80 220/380 2.4

1.2

220
AX-DD30-S303 9000(7740) 31 6 3

300

3×1800 9 80 220/380 2.7 1.2 220
AX-DD40-S304 12000(10300) 405 6 4 300 4×1800 9 80 220/380 3.0 1.5 220
AX-DD45-S304 13500(11600) 44.5 6 4 300 4×1800 9 80 220/380 3.6 1.5 220
AX-DD60-S404 18000(15500) 61 6 4 400 4×3600 14 180 220/380 6.5 1.5 220
AX-DD75-S404 22500(19400) 75 6 4 400 4×3600 14 180 220/380 6.5 1.5 220
AX-DD90-S404 27000(23200) 89 6 4 400 4×3600 14 180 220/380 9.0 1.8 220
AX-DD105-S454 31500(27100) 106 6 4 450 4×5200 18 250 220/380 9.0 1.8 220
AX-DD120-S454 36000(31000) 121 6 4 450 4×5200 18 250 220/380 9.0 1.8 220
AX-DD135-S455 39000(33500) 134.5 6 5 450 5×5200 18 250 220/380 10.0 1.8 220
AX-DD145-S455 42000(36100) 143.5 6 5 450 5×5200 18 250 220/380 12.5 2.5 220
AX-DD160-S455 44800(38500) 158 6 5 450 5×5200 18 250 220/380 12.5 2.5 220
AX-DD185-S505 51800(44500) 187 6 5 500 5×6500 20 400 220/380 15.0 2.5 220
AX-DD200-S505 56000(48200) 203 6 5 500 5×6500 20 400 220/380 20.0 2.5 220
As for the refrigerating capacity of R22 under condition of tk=-18℃ and △t=7℃, the refrigerating capacity of R134a should be multiplied the correction factor Qor 134a=Qor 22×f

Correction factor Table f
R134a
蒸发温度to >-12℃ >-17℃ >-22℃ >-27℃
Qo 1.00 0.96 0.93 0.90

New and High-performance Series Air Cooler
Main Technical Parameter of DJ Series Air-Cooler
型号Model 名义制冷量
W(Kcal/h)
冷却面积 片距 风扇电机Fan Motor 电热管heating tube 备注
数量 直径Φ 风量 射程 电机功率 电压 盘管 水盘 电压
m2 mm mm m3/h m W V KW KW V 可用于
R134a
R404A
R407C

R502
AX-DJ7-S301 1960(1680) 6.3 9 1 300 1800 9 80 220/380 1.2 0.6 220
AX-DJ9-S351 2520(2170) 8.2 9 1 360 2500 12 160 220/380 1.8 0.9 220
AX-DJ10-S302 2800(2400) 10 9 2 300 2×1800 9 80 220/380 1.8 0.9 220
AX-DJ15-S302 4200(3600) 15 9 2 300 2×1800 9 80 220/380 2.4 1.2 220
AX-DJ22-S303 6160(5300) 21 9 3 300 3×1800 9 80 220/380 3.0 1.2 220
AX-DJ27-S304 7560(6500) 27 9 4 300 4×1800 9 80 220/380 3.0 1.2 220
AX-DJ30-S304 8400(7220) 30 9 4 300 4×1800 9 80 220/380 3.6 1.5 220
AX-DJ40-S404 11200(9630) 40.5 9 4 400 4×3600 14 180 220/380 4.5 1.5 220
AX-DJ50-S404 14000(12000) 50 9 4 400 4×3600 14 180 220/380 6.5 1.8 220
AX-DJ60-S404 16800(14400) 60 9 4 400 4×3600 14 180 220/380 7.5 1.8 220
AX-DJ70-S454 18900(16200) 71 9 4 450 4×5200 18 250 220/380 9.0 1.8 220
AX-DJ80-S454 21600(18600) 81 9 4 450 4×5200 18 250 220/380 9.0 1.8 220
AX-DJ90-S455 24300(21000) 89 9 5 450 5×5200 18 250 220/380 12.5 2.5 220
AX-DJ95-S455 24900(21400) 95 9 5 450 5×5200 18 250 220/380 12.5 2.5 220
AX-DJ105-S455 27300(23500) 104 9 5 450 5×5200 18 250 220/380 15.0 2.5 220
AX-DJ125-S505 32500(27900) 125 9 5 500 5×6500 20 400 220/380 20.0 2.5 220
AX-DJ135-S505 35100(30200) 135 9 5 500 5×6500 20 400 220/380 22.5 2.5 220
As for the refrigerating capacity of R22 under condition of tk=-25℃ and △t=7℃, the refrigerating capacity of R134a should be multiplied the correction factor Qor 134a=Qor 22×f

Correction factor Table f
R134a
蒸发温度to >-12℃ >-17℃ >-22℃ >-27℃
Qo 1.00 0.96 0.93 0.90

New and High-performance Series Air Cooler
Main Technical Parameter of DL Series Air-Cooler
型号Model 名义制冷量
W(Kcal/h)
冷却面积 片距 风扇电机Fan Motor 电热管heating tube 备注
数量 直径Φ 风量 射程 电机功率 电压 盘管 水盘 电压
m2 mm mm m3/h m W V KW KW V 可用于
R134a
R404A
R407C

R502
AX-DL12-S301 3840(3300) 12 4.5 1 300 1800 9 80 220/380 0.6 0.6 220
AX-DL16-S351 5120(4400) 16 4.5 1 350 2500 12 150 220/380 0.9 0.6 220
AX-DL20-S302 6400(5500) 20 4.5 2 300 2×1800 9 80 220/380 0.9 0.6 220
AX-DL30-S302 9600(8250) 30 4.5 2 300 2×1800 9 80 220/380 1.2 0.6 220
AX-DL45-S303 14400(12400) 42 4.5 3 300 3×1800 9 80 220/380 1.8 0.9 220
AX-DL55-S304 17600(15100) 54 4.5 4 300 4×1800 9 80 220/380 1.8 0.9 220
AX-DL60-S304 19200(16500) 60 4.5 4 300 4×1800 9 80 220/380 2.4 1.2 220
AX-DL80-S404 25600(22000) 81 4.5 4 400 4×3600 14 180 220/380 2.4 1.2 220
AX-DL100-S404 32000(27500) 100 4.5 4 400 4×3600 14 180 220/380 3.6 1.5 220
AX-DL120-S404 36000(31000) 118 4.5 4 400 4×3600 14 180 220/380 5.0 1.8 220
AX-DL140-S454 42000(36100) 142 4.5 4 450 4×5200 18 250 220/380 5.0 1.8 220
AX-DL160-S454 48000(41300) 162 4.5 4 450 4×5200 18 250 220/380 6.5 1.8 220
AX-DL180-S455 54000(46400) 178 4.5 5 450 5×5200 18 250 220/380 6.5 1.8 220
AX-DL190-S455 57000(49000) 191 4.5 5 450 5×5200 18 250 220/380 7.5 2.5 220
AX-DL210-S455 63000(54200) 208 4.5 5 450 5×5200 18 250 220/380 7.5 2.5 220
AX-DL250-S505 75000(64500) 249 4.5 5 500 5×6500 20 400 220/380 9.0 2.5 220
AX-DL270-S505 81000(69700) 270 4.5 5 500 5×6500 20 400 220/380 10.0 2.5 220
As for the refrigerating capacity of R22 under condition of tk=0℃ and △t=7℃, the refrigerating capacity of R134a should be multiplied the correction factor Qor 134a=Qor 22×f

Correction factor Table f
R134a
蒸发温度to >-12℃ >-17℃ >-22℃ >-27℃
Qo 1.00 0.96 0.93 0.90

Installation Size of New and High-performance Series Air Cooler
Technical Parameters
型号Model A B C D E E1 E2 F 进液直径Φ(mm) 回气直径Φ(mm) 出水管直径Φ
AX-DL12-S301
AX-DD9-S301
AX-DJ7-S301
820 400 470 370 510 155 12 19 G1"
AX-DL16-S351
AX-DD12-S351
AX-DJ9-S351
880 400 540 370 570 155 12 22
AX-DL20-S302
AX-DD15-S302
AX-DJ10-S302
1000 400 540 370 690 155 12 22
AX-DL30-S302
AX-DD22-S302
AX-DJ15-S302
1320 400 540 370 1010 155 12 22

AX-DL45-S303
AX-DD30-S303
AX-DJ22-S303

1720 400 540 370 1410 155 16 28

AX-DL55-S304
AX-DD40-S304
AX-DJ27-S304

2100 400 540 370 1790 880 155 16 28
AX-DL60-S304
AX-DD45-S304
AX-DJ30-S304
2300 400 540 370 1990 980 155 16 28
AX-DL80-S404
AX-DD60-S404
AX-DJ40-S404
2420 410 680 370 2110 1040 155 16 32

AX-DL100-S404
AX-DD75-S404
AX-DJ50-S404

2900 410 680 370 2590 1280 155 22 32
AX-DL120-S404
AX-DD90-S404
AX-DJ60-S404
3040 410 750 370 2730 1350 155 22 32
AX-DL140-S454
AX-DD105-S454
AX-DJ70-S454
3040 420 890 370 2730 1350 155 22 32
AX-DL160-S454
AX-DD120-S454
AX-DJ80-S454
2820 480 890 430 2510 1240 155 22 32
AX-DL180-S455
AX-DD135-S455
AX-DJ90-S455
3040 480 890 430 2730 1080 540 155 25 42 G3/2"
AX-DL190-S455
AX-DD145-S455
AX-DJ95-S455
3240 480 890 430 2930 1160 580 155 25 42

AX-DL210-S455
AX-DD160-S455
AX-DJ105-S455

3490 480 890 430 3180 1260 630 155 25 42
AX-DL250-S505
AX-DD185-S505
AX-DJ125-S505
3490 550 890 480 3180 1260 630 155 25 50
AX-DL270-S505
AX-DD200-S505
AX-DJ135-S505
3490 550 960 480 3180 1260 630 155 25 50
Note: We reserve the right to make technical modification without prior notice.
更多产品